<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-27 09-19-30
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 4/5, 40 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
5 kHz 58 kHz 12709 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,5 dBr -0,20 dBr 0,3 dBr 0,1
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 9:19, 27.09.2026
RT
"Tyden Plus - Vyber udalosti poslednich sedmi dnu pripravila V..."
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 58 kHz MIN: 5 kHz % above 77 kHz: 0,0000 Acquired: 2026/09/27 9:19:24 Total samples: 12709 Equivalent time: 0:10:35 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 0,3 dBr MIN: -0,5 dBr AVE: -0,20 dBr % above 0,2 dBr: 0,1 Last value: -0,4 dBr (2026/09/27 9:19:24) 09:06 09:08 09:10 09:12 09:14 09:16 09:18 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality